Product series • Delta
Delta AC Drives VFD-EL, MS300, MH300 and C2000
Delta AC drives are used across Egyptian factories for pumps, fans, conveyors and machines. This page lists the Delta drives on our site from the compact VFD-EL to the C2000.
In most codes the digits after VFD give the power (VFD015 = 1.5 kW) and the two digits after the series give the supply: 21 = 230 V single-phase, 23 = 230 V three-phase, 43 = 460 V three-phase.
How to choose
- Power and supply: match the motor kW and current, and the supply you have (single-phase 230 V or three-phase 400 V).
- Series: VFD-EL for small machines, MS300 as a compact standard drive, MH300 as a compact high-performance drive, C2000 for heavier loads and advanced vector control.
- Send us: the motor kW and current, the supply and the load, or the code of the old drive.
Can't find your code? Send the part number or a photo of the old part.
Part numbers we supply (75)
| Part number | Series | Power, current, supply | |
|---|---|---|---|
| VFD007EL21A | VFD-EL | 0.75 kW, 5 A, 230 V 1-phase | |
| VFD007EL43A | VFD-EL | 0.75 kW, 2.5 A, 460 V 3-phase | |
| VFD015EL21A | VFD-EL | 1.5 kW, 7.5 A, 230 V 1-phase | |
| VFD015EL43A | VFD-EL | 1.5 kW, 4.2 A, 460 V 3-phase | |
| VFD022EL21A | VFD-EL | 2.2 kW, 11 A, 230 V 1-phase | |
| VFD022EL43A | VFD-EL | 2.2 kW, 5.5 A, 460 V 3-phase | |
| VFD037EL23A | VFD-EL | 3.7 kW, 17 A, 230 V 3-phase | |
| VFD037EL43A | VFD-EL | 7 kW, 8.2 A, 460 V 3-phase | |
| VFD007EL43W-1 | VFD-EL-W | 0.75 kW, 2.5 A, 460 V 3-phase | |
| VFD007EL21W-1 | VFD-EL-W | 0.75 kW (1 HP), 230 V 1-phase | |
| VFD015EL21W-1 | VFD-EL-W | 1.5 kW, 7.5 A, 230 V 1-phase | |
| VFD015EL43W-1 | VFD-EL-W | 1.5 kW, 4.2 A, 460 V 3-phase | |
| VFD022EL21W-1 | VFD-EL-W | 2.2 kW, 11 A, 230 V 1-phase | |
| VFD022EL43W-1 | VFD-EL-W | 2.2 kW (3 HP), 460 V 3-phase | |
| VFD040EL43W-1 | VFD-EL-W | 4 kW, 9 A, 460 V 3-phase | |
| VFD055EL43W-1 | VFD-EL-W | 5.5 kW, 11 A, 460 V 3-phase | |
| VFD2A7MS43ANSAA | MS300 | 0.75 kW, 2.7 A, 460 V 3-phase | |
| VFD4A8MS21ANSAA | MS300 | 0.75 kW (1 HP), 230 V 1-phase | |
| VFD7A5MS21ANSAA | MS300 | 1.5 kW, 7.5 A, 230 V 1-phase | |
| VFD4A2MS43ANSAA | MS300 | 1.5 kW, 4.2 A, 460 V 3-phase | |
| VFD11AMS21ANSAA | MS300 | 2.2 kW, 11 A, 230 V 1-phase | |
| VFD5A5MS43ANSAA | MS300 | 2.2 kW, 5.5 A, 460 V 3-phase | |
| VFD17AMS23ANSAA | MS300 | 3.7 kW, 17 A, 230 V 3-phase | |
| VFD9A0MS43ANSAA | MS300 | 3.7 kW (5 HP), 460 V 3-phase | |
| VFD25AMS23ANSAA | MS300 | 5.5 kW, 25 A, 230 V 3-phase | |
| VFD13AMS43ANSAA | MS300 | 5.5 kW, 13 A, 460 V 3-phase | |
| VFD33AMS23ANSAA | MS300 | 7.5 kW, 33 A, 230 V 3-phase | |
| VFD17AMS43ANSAA | MS300 | 7.5 kW, 17 A, 460 V 3-phase | |
| VFD49AMS23ANSAA | MS300 | 11 kW, 49 A, 230 V 3-phase | |
| VFD25AMS43ANSAA | MS300 | 11 kW, 25 A, 460 V 3-phase | |
| VFD65AMS23ANSAA | MS300 | 15 kW, 65 A, 230 V 3-phase | |
| VFD32AMS43ANSAA | MS300 | 15 kW, 32 A, 460 V 3-phase | |
| VFD38AMS43ANSAA | MS300 | 18.5 kW, 38 A, 460 V 3-phase | |
| VFD45AMS43ANSAA | MS300 | 22 kW, 45 A, 460 V 3-phase | |
| VFD3A0MH43ANSAA | MH300 | 0.75 kW, 2.7 A, 460 V 3-phase | |
| VFD4A2MH43ANSAA | MH300 | 1.5 kW, 4.2 A, 460 V 3-phase | |
| VFD5A7MH43ANSAA | MH300 | 2.2 kW, 5.5 A, 460 V 3-phase | |
| VFD9A0MH43ANSAA | MH300 | 3.7 kW, 9 A, 460 V 3-phase | |
| VFD13AMH43ANSAA | MH300 | 5.5 kW, 13 A, 460 V 3-phase | |
| VFD17AMH43ANSAA | MH300 | 7.5 kW, 17 A, 460 V 3-phase | |
| VFD25AMH43ANSAA | MH300 | 11 kW, 25 A, 460 V 3-phase | |
| VFD32AMH43ANSAA | MH300 | 15 kW, 32 A, 460 V 3-phase | |
| VFD38AMH43ANSAA | MH300 | 18.5 kW, 38 A, 460 V 3-phase | |
| VFD45AMH43ANSAA | MH300 | 22 kW, 45 A, 460 V 3-phase | |
| VFD60AMH43ANSAA | MH300 | 30 kW, 60 A, 460 V 3-phase | |
| VFD75AMH43ANSAA | MH300 | 37 kW, 75 A, 460 V 3-phase | |
| VFD91AMH43ANSAA | MH300 | 45 kW, 91 A, 460 V 3-phase | |
| VFD112MH43ANSAA | MH300 | 55 kW, 112 A, 460 V 3-phase | |
| VFD150MH43ANSAA | MH300 | 75 kW, 150 A, 460 V 3-phase | |
| VFD007C43A | C2000 | 0.75 kW, 3 A, 460 V 3-phase | |
| VFD015C43A | C2000 | 1.5 kW, 4 A, 460 V 3-phase | |
| VFD022C43A | C2000 | 2.2 kW, 6 A, 460 V 3-phase | |
| VFD037C43A | C2000 | 3.7 kW, 9 A, 460 V 3-phase | |
| VFD055C43A | C2000 | 5.5 kW, 12 A, 460 V 3-phase | |
| VFD075C23A | C2000 | 7.5 kW, 33 A, 230 V 3-phase | |
| VFD075C43A | C2000 | 7.5 kW (10 HP), 460 V 3-phase | |
| VFD110C23A | C2000 | 11 kW, 49 A, 230 V 3-phase | |
| VFD110C43A | C2000 | 11 kW, 24 A, 460 V 3-phase | |
| VFD150C23A | C2000 | 15 kW, 65 A, 230 V 3-phase | |
| VFD150C43A | C2000 | 15 kW, 32 A, 460 V 3-phase | |
| VFD185C43A | C2000 | 18.5 kW, 38 A, 460 V 3-phase | |
| VFD220C43A | C2000 | 22 kW (30 HP), 460 V 3-phase | |
| VFD300C43A | C2000 | 30 kW, 60 A, 460 V 3-phase | |
| VFD370C43S | C2000 | 37 kW, 73 A, 460 V 3-phase | |
| VFD450C43S | C2000 | 45 kW, 91 A, 460 V 3-phase | |
| VFD550C43A | C2000 | 55 kW, 110 A, 460 V 3-phase | |
| VFD750C43A | C2000 | 75 kW, 150 A, 460 V 3-phase | |
| VFD900C43A | C2000 | 90 kW, 180 A, 460 V 3-phase | |
| VFD1100C43A | C2000 | 110 kW, 220 A, 460 V 3-phase | |
| VFD1320C43A | C2000 | 132 kW, 260 A, 460 V 3-phase | |
| VFD1600C43A | C2000 | 160 kW, 310 A, 460 V 3-phase | |
| VFD2200C43A | C2000 | 220 kW, 460 A, 460 V 3-phase | |
| VFD2800C43A | C2000 | 280 kW, 550 A, 460 V 3-phase | |
| VFD3150C43A | C2000 | 315 kW, 616 A, 460 V 3-phase | |
| VFD3550C43A | C2000 | 355 kW, 683 A, 460 V 3-phase |