Product series • Pizzato

Pizzato CS Safety Modules (Safety Relays)

A safety module (safety relay) mounts in the control panel and monitors the emergency stop buttons and guard door switches. If one of them opens, the module opens its outputs and stops the machine.

Most of our CS AR modules are for gate and emergency stop monitoring at category 4, PL e, SIL 3, with 24 Vac/dc or 230 Vac supply and screw terminals, per the manufacturer.

How to choose

  1. Function: gate and emergency stop monitoring (CS AR), delayed outputs (CS AT), two-hand control for presses (CS DM), or timer (CS FS).
  2. Category: as your machine’s risk assessment requires (category 3 or 4).
  3. Outputs: how many NO outputs switch your contactors, plus NC if you need a signal to the PLC.
  4. Supply: 24 Vac/dc or 230 Vac, to match your panel.

Can't find your code? Send the part number or a photo of the old part.

Part numbers we supply (15)

Part numberFunctionOutputs, supply
CS AR-01V024 Gate and emergency stop monitoring, category 4, PL e, SIL 3 2NO+1NC, supply 24 Vac/dc
CS AR-02V024 Gate and emergency stop monitoring, category 4, PL e, SIL 3 3NO, supply 24 Vac/dc
CS AR-04V024 Gate and emergency stop monitoring, category 4, PL e, SIL 3 3NO+1NC, supply 24 Vac/dc
CS AR-05V024 Gate and emergency stop monitoring, category 4, PL e, SIL 3 3NO+1NC, supply 24 Vac/dc
CS AR-06V024 Gate and emergency stop monitoring, category 4, PL e, SIL 3 3NO+1NC, supply 24 Vac/dc
CS AR-08V024 Gate and emergency stop monitoring, category 4, PL e, SIL 3 2NO, supply 24 Vac/dc
CS AR-01V230 Gate and emergency stop monitoring, category 4, PL e, SIL 3 2NO+1NC, supply 230 Vac
CS AR-08V230 Gate and emergency stop monitoring, category 4, PL e, SIL 3 2NO, supply 230 Vac
CS AR-20V024 Gate and emergency stop monitoring, category 3, PL e, SIL 3 2NO, supply 24 Vac/dc
CS AR-24V024 Gate and emergency stop monitoring, category 3, PL e, SIL 3 4NO+1NC, supply 24 Vac/dc
CS AR-25V024 Gate and emergency stop monitoring, category 3, PL e, SIL 3 4NO+1NC, supply 24 Vac/dc
CS FS-53VU24 Safety timer module, category 3 1NO+1NC+1CO, supply 24 Vac/dc
CS DM-01V024 Two-hand control monitoring, type III C (EN ISO 13851) 3NO+1NC, supply 24 Vac/dc
CS AT-01V024 Safety module, category 4, with delayed outputs 2NO+1NC + 2NO delayed, supply 24 Vac/dc
CS AT-31V024 Gate and emergency stop monitoring, category 4, with delayed outputs 2NO + 1NO delayed, supply 24 Vac/dc