Product series • Schneider Electric

Schneider Acti9 iC60 Miniature Circuit Breakers (MCB)

Schneider Acti9 iC60 breakers (A9F codes) are miniature circuit breakers (MCB) for distribution and control panels, from 1 to 63 A, in 1, 2, 3 or 4 poles.

There are three ranges by breaking capacity, per the manufacturer: iC60N (6000 A IEC 60898-1 / 10 kA IEC 60947-2), iC60H (10000 A / 15 kA) and iC60L (15000 A / 25 kA).

How to choose

  1. Current: to suit the cable size and load (for example 16 A for a socket circuit, 32 A for a large air conditioner).
  2. Curve: B for general loads and lighting, C for small motors and loads with inrush current, D for very high inrush loads such as transformers.
  3. Breaking capacity: iC60N for sub-distribution, iC60H or iC60L where the short-circuit current is high (near the transformer or main board).
  4. Poles: 1P for single circuits, 2P for phase and neutral, 3P for three-phase, 4P for three-phase with neutral.

Can't find your code? Send the part number or a photo of the old part.

Part numbers we supply (111)

Part numberRange, poles, breaking capacityRated current, curve
A9F73404 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 4 A, curve B
A9F74101 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 1 A, curve C
A9F74102 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 2 A, curve C
A9F74103 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 3 A, curve C
A9F74104 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 4 A, curve C
A9F74201 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 1 A, curve C
A9F74202 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 2 A, curve C
A9F74203 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 3 A, curve C
A9F74204 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 4 A, curve C
A9F74302 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 2 A, curve C
A9F74303 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 3 A, curve C
A9F74402 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 2 A, curve C
A9F74404 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 4 A, curve C
A9F76110 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 10 A, curve B
A9F76116 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 16 A, curve B
A9F77106 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 6 A, curve C
A9F77110 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 10 A, curve C
A9F77116 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 16 A, curve C
A9F77120 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 20 A, curve C
A9F77125 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 25 A, curve C
A9F77132 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 32 A, curve C
A9F77140 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 40 A, curve C
A9F77150 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 50 A, curve C
A9F77163 iC60N, 1-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 63 A, curve C
A9F77206 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 6 A, curve C
A9F77210 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 10 A, curve C
A9F77216 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 16 A, curve C
A9F77220 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 20 A, curve C
A9F77225 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 25 A, curve C
A9F77232 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 32 A, curve C
A9F77240 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 40 A, curve C
A9F77250 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 50 A, curve C
A9F77263 iC60N, 2-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 63 A, curve C
A9F77306 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 6 A, curve C
A9F77310 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 10 A, curve C
A9F77316 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 16 A, curve C
A9F77320 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 20 A, curve C
A9F77325 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 25 A, curve C
A9F77332 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 32 A, curve C
A9F77340 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 40 A, curve C
A9F77350 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 50 A, curve C
A9F77363 iC60N, 3-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 63 A, curve C
A9F77406 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 6 A, curve C
A9F77410 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 10 A, curve C
A9F77416 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 16 A, curve C
A9F77420 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 20 A, curve C
A9F77425 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 25 A, curve C
A9F77432 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 32 A, curve C
A9F77440 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 40 A, curve C
A9F77450 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 50 A, curve C
A9F77463 iC60N, 4-pole, 6000 A IEC 60898-1 / 10 kA IEC 60947-2 63 A, curve C
A9F87106 iC60H, 1-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 6 A, curve C
A9F87110 iC60H, 1-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 10 A, curve C
A9F87116 iC60H, 1-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 16 A, curve C
A9F87120 iC60H, 1-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 20 A, curve C
A9F87125 iC60H, 1-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 25 A, curve C
A9F87132 iC60H, 1-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 32 A, curve C
A9F87140 iC60H, 1-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 40 A, curve C
A9F87150 iC60H, 1-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 50 A, curve C
A9F87163 iC60H, 1-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 63 A, curve C
A9F87206 iC60H, 2-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 6 A, curve C
A9F87210 iC60H, 2-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 10 A, curve C
A9F87216 iC60H, 2-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 16 A, curve C
A9F87220 iC60H, 2-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 20 A, curve C
A9F87225 iC60H, 2-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 25 A, curve C
A9F87232 iC60H, 2-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 32 A, curve C
A9F87240 iC60H, 2-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 40 A, curve C
A9F87263 iC60H, 2-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 63 A, curve C
A9F87306 iC60H, 3-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 6 A, curve C
A9F87310 iC60H, 3-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 10 A, curve C
A9F87316 iC60H, 3-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 16 A, curve C
A9F87320 iC60H, 3-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 20 A, curve C
A9F87325 iC60H, 3-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 25 A, curve C
A9F87332 iC60H, 3-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 32 A, curve C
A9F87340 iC60H, 3-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 40 A, curve C
A9F87350 iC60H, 3-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 50 A, curve C
A9F87363 iC60H, 3-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 63 A, curve C
A9F87410 iC60H, 4-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 10 A, curve C
A9F87416 iC60H, 4-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 16 A, curve C
A9F87420 iC60H, 4-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 20 A, curve C
A9F87425 iC60H, 4-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 25 A, curve C
A9F87432 iC60H, 4-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 32 A, curve C
A9F87440 iC60H, 4-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 40 A, curve C
A9F87450 iC60H, 4-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 50 A, curve C
A9F87463 iC60H, 4-pole, 10000 A IEC 60898-1 / 15 kA IEC 60947-2 63 A, curve C
A9F90276 iC60L MA, 2-pole, magnetic-only (motor) 6.3 A
A9F90373 iC60L MA, 3-pole, magnetic-only (motor) 2.5 A
A9F90376 iC60L MA, 3-pole, magnetic-only (motor) 6.3 A
A9F95102 iC60L, 1-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 2 A, curve D
A9F94110 iC60L, 1-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 10 A, curve C
A9F94116 iC60L, 1-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 16 A, curve C
A9F94120 iC60L, 1-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 20 A, curve C
A9F94125 iC60L, 1-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 25 A, curve C
A9F94132 iC60L, 1-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 32 A, curve C
A9F94140 iC60L, 1-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 40 A, curve C
A9F94163 iC60L, 1-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 63 A, curve C
A9F94203 iC60L, 2-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 3 A, curve C
A9F94210 iC60L, 2-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 10 A, curve C
A9F94216 iC60L, 2-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 16 A, curve C
A9F94220 iC60L, 2-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 20 A, curve C
A9F94310 iC60L, 3-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 10 A, curve C
A9F94316 iC60L, 3-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 16 A, curve C
A9F94320 iC60L, 3-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 20 A, curve C
A9F94325 iC60L, 3-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 25 A, curve C
A9F94332 iC60L, 3-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 32 A, curve C
A9F94340 iC60L, 3-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 40 A, curve C
A9F94350 iC60L, 3-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 50 A, curve C
A9F94363 iC60L, 3-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 63 A, curve C
A9F94410 iC60L, 4-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 10 A, curve C
A9F94440 iC60L, 4-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 40 A, curve C
A9F94463 iC60L, 4-pole, 15000 A IEC 60898-1 / 25 kA IEC 60947-2 63 A, curve C

Acti9 iC60 MCB: common questions

How do I read an Acti9 A9F code?

The last two digits are the rating in amps and the digit before them is the number of poles. Example: A9F77440 = 4-pole, 40 A; A9F74104 = 1-pole, 4 A. The digits right after A9F give the range and curve, for example A9F74 and A9F77 = iC60N curve C, A9F87 = iC60H curve C, A9F94 = iC60L curve C.

What is the difference between iC60N, iC60H and iC60L?

The breaking capacity, per Schneider: iC60N 6000 A (IEC 60898-1) / 10 kA (IEC 60947-2), iC60H 10000 A / 15 kA, iC60L 15000 A / 25 kA. iC60N suits sub-distribution boards; use iC60H or iC60L where the short-circuit current is high, near the transformer or main board.

Curve B, C or D: which one do I need?

B for general loads and lighting, C for small motors and loads with inrush current, D for very high inrush loads such as transformers. Curve C is the most common choice in our list.

How many poles do I need?

1P for a single circuit, 2P for phase and neutral, 3P for three-phase, 4P for three-phase with neutral.

What is iC60L MA?

A magnetic-only version for motor circuits, in 2 and 3 poles in our list. It gives short-circuit protection only, so the motor also needs an overload relay.