Schneider TeSys D Contactors (LC1D)
The Schneider TeSys D contactor (LC1D codes) is one of the most used contactors in motor control panels in Egypt. We list 3-pole types from 9 to 150 A AC-3, 4-pole AC-1 types, and capacitor duty contactors for power factor correction banks.
The number in the code is the current: LC1D09 = 9 A AC-3, LC1D32 = 32 A. The last letters give the coil voltage: M7 = 220 V AC, Q7 = 380 V AC, F7 = 110 V AC, B7 = 24 V AC and BD = 24 V DC.
How to choose
- Current and power: choose the contactor by its AC-3 (motor duty) current, equal to or above the motor nameplate current, or by AC-1 for resistive loads such as heaters.
- Coil voltage: must match your control circuit (for example 220 V AC or 24 V DC). The wrong voltage burns the coil or the contactor does not pull in.
- Auxiliary contacts: the NO and NC contacts you need for control and signals; add an auxiliary block if you need more.
- Capacitors: for power factor correction banks, use the capacitor duty contactor rated in kvar.
Can't find your code? Send the part number or a photo of the old part.
Part numbers we supply (142)
| Part number | Poles, rating | Coil; auxiliary contacts | |
|---|---|---|---|
| LC1D09B7 | 3-pole, AC-3 9 A / 4 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D09BD | 3-pole, AC-3 9 A / 4 kW | Coil 24 V DC; aux 1NO+1NC | |
| LC1D09E7 | 3-pole, AC-3 9 A / 4 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D09F7 | 3-pole, AC-3 9 A / 4 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D09FD | 3-pole, AC-3 9 A / 4 kW | Coil 110 V DC; aux 1NO+1NC | |
| LC1D09M7 | 3-pole, AC-3 9 A / 4 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D09MD | 3-pole, AC-3 9 A / 4 kW | Coil 220 V DC; aux 1NO+1NC | |
| LC1D09P7 | 3-pole, AC-3 9 A / 4 kW | Coil 230 V AC; aux 1NO+1NC | |
| LC1D09Q7 | 3-pole, AC-3 9 A / 4 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D115004M7 | 4-pole, 4NO | Coil 220 V AC | |
| LC1D115B7 | 3-pole, AC-3 115 A / 55 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D115BD | 3-pole, AC-3 115 A | Coil 24 V DC | |
| LC1D115E7 | 3-pole, AC-3 115 A / 55 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D115F7 | 3-pole, AC-3 115 A / 55 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D115M7 | 3-pole, AC-3 115 A / 55 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D115Q7 | 3-pole, AC-3 115 A / 55 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D128B7 | 4-pole, AC-1 25 A, 2NO+2NC | Coil 24 V AC | |
| LC1D128BD | 4-pole, AC-1 25 A, 2NO+2NC | Coil 24 V DC | |
| LC1D128E7 | 4-pole, AC-1 25 A, 2NO+2NC | Coil 48 V AC | |
| LC1D128F7 | 4-pole, AC-1 25 A, 2NO+2NC | Coil 110 V AC | |
| LC1D128M7 | 4-pole, AC-1 25 A, 2NO+2NC | Coil 220 V AC | |
| LC1D12B7 | 3-pole, AC-3 12 A / 5.5 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D12BD | 3-pole, AC-3 12 A / 5.5 kW | Coil 24 V DC; aux 1NO+1NC | |
| LC1D12E7 | 3-pole, AC-3 12 A / 5.5 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D12F7 | 3-pole, AC-3 12 A / 5.5 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D12M7 | 3-pole, AC-3 12 A / 5.5 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D12MD | 3-pole, AC-3 12 A / 5.5 kW | Coil 220 V DC; aux 1NO+1NC | |
| LC1D12Q7 | 3-pole, AC-3 12 A / 5.5 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D150B7 | 3-pole, AC-3 150 A / 75 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D150E7 | 3-pole, AC-3 150 A / 75 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D150F7 | 3-pole, AC-3 150 A / 75 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D150M7 | 3-pole, AC-3 150 A / 75 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D150Q7 | 3-pole, AC-3 150 A / 75 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D18B7 | 3-pole, AC-3 18 A / 7.5 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D18BD | 3-pole, AC-3 18 A / 7.5 kW | Coil 24 V DC; aux 1NO+1NC | |
| LC1D18E7 | 3-pole, AC-3 18 A / 7.5 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D18F7 | 3-pole, AC-3 18 A / 7.5 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D18FD | 3-pole, AC-3 18 A / 9 kW | Coil 110 V DC; aux 1NO+1NC | |
| LC1D18M7 | 3-pole, AC-3 18 A / 7.5 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D18MD | 3-pole, AC-3 18 A / 9 kW | Coil 220 V DC; aux 1NO+1NC | |
| LC1D18Q7 | 3-pole, AC-3 18 A / 7.5 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D258B7 | 4-pole, AC-1 40 A, 2NO+2NC | Coil 24 V AC | |
| LC1D258E7 | 4-pole, AC-1 40 A, 2NO+2NC | Coil 48 V AC | |
| LC1D258F7 | 4-pole, AC-1 40 A, 2NO+2NC | Coil 110 V AC | |
| LC1D258M7 | 4-pole, AC-1 40 A, 2NO+2NC | Coil 220 V AC | |
| LC1D25B7 | 3-pole, AC-3 25 A / 11 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D25BD | 3-pole, AC-3 25 A / 11 kW | Coil 24 V DC; aux 1NO+1NC | |
| LC1D25E7 | 3-pole, AC-3 25 A / 11 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D25F7 | 3-pole, AC-3 25 A / 11 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D25M7 | 3-pole, AC-3 25 A / 11 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D25P7 | 3-pole, AC-3 25 A / 11 kW | Coil 230 V AC; aux 1NO+1NC | |
| LC1D25Q7 | 3-pole, AC-3 25 A / 11 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D32B7 | 3-pole, AC-3 32 A / 15 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D32BD | 3-pole, AC-3 32 A / 15 kW | Coil 24 V DC; aux 1NO+1NC | |
| LC1D32E7 | 3-pole, AC-3 32 A / 15 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D32ED | 3-pole, AC-3 32 A / 15 kW | Coil 48 V DC; aux 1NO+1NC | |
| LC1D32F7 | 3-pole, AC-3 32 A / 15 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D32FD | 3-pole, AC-3 32 A / 15 kW | Coil 110 V DC; aux 1NO+1NC | |
| LC1D32M7 | 3-pole, AC-3 32 A / 15 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D32MD | 3-pole, AC-3 32 A / 15 kW | Coil 220 V DC; aux 1NO+1NC | |
| LC1D32Q7 | 3-pole, AC-3 32 A / 15 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D38B7 | 3-pole, AC-3 38 A / 18.5 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D38BD | 3-pole, AC-3 38 A / 18.5 kW | Coil 24 V DC; aux 1NO+1NC | |
| LC1D38E7 | 3-pole, AC-3 38 A / 18.5 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D38F7 | 3-pole, AC-3 38 A / 18.5 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D38M7 | 3-pole, AC-3 38 A / 18.5 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D38Q7 | 3-pole, AC-3 38 A / 18.5 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D40004P7 | 4-pole, 4NO | Coil 230 V AC | |
| LC1D40008E7 | 4-pole, AC-1 60 A, 2NO+2NC | Coil 48 V AC | |
| LC1D40008F7 | 4-pole, AC-1 60 A, 2NO+2NC | Coil 110 V AC | |
| LC1D40008M7 | 4-pole, AC-1 60 A, 2NO+2NC | Coil 220 V AC | |
| LC1D40A3M7 | 3-pole, AC-3 40 A, spring terminals | Coil 220 V AC | |
| LC1D40AB7 | 3-pole, AC-3 40 A / 18.5 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D40ABNE | 3-pole, AC-3 40 A / 18.5 kW | Coil 24-60 V AC/DC; aux 1NO+1NC | |
| LC1D40AE7 | 3-pole, AC-3 40 A / 18.5 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D40AF7 | 3-pole, AC-3 40 A / 18.5 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D40AM7 | 3-pole, AC-3 40 A / 18.5 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D40AQ7 | 3-pole, AC-3 40 A / 18.5 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D50A6M7 | 3-pole, AC-3 50 A / 22 kW, lug terminals | Coil 220 V AC | |
| LC1D50AB7 | 3-pole, AC-3 50 A / 22 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D50ABNE | 3-pole, AC-3 50 A / 22 kW | Coil 24-60 V AC/DC; aux 1NO+1NC | |
| LC1D50AE7 | 3-pole, AC-3 50 A / 22 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D50AF7 | 3-pole, AC-3 50 A / 22 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D50AM7 | 3-pole, AC-3 50 A / 22 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D50AQ7 | 3-pole, AC-3 50 A / 22 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D65008E7 | 4-pole, 2NO+2NC | Coil 48 V AC | |
| LC1D65008F7 | 4-pole, 2NO+2NC | Coil 110 V AC | |
| LC1D65008M7 | 4-pole, AC-1 80 A, 2NO+2NC | Coil 220 V AC | |
| LC1D65AB7 | 3-pole, AC-3 65 A / 30 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D65ABNE | 3-pole, AC-3 65 A / 30 kW | Coil 24-60 V AC/DC; aux 1NO+1NC | |
| LC1D65AE7 | 3-pole, AC-3 65 A / 30 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D65AF7 | 3-pole, AC-3 65 A / 30 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D65AM7 | 3-pole, AC-3 65 A / 30 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D65AP7 | 3-pole, AC-3 65 A / 30 kW | Coil 230 V AC | |
| LC1D65AQ7 | 3-pole, AC-3 65 A / 30 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D80004E7 | 4-pole, AC-1 125 A, 4NO | Coil 48 V AC | |
| LC1D80004F7 | 4-pole, AC-1 125 A, 4NO | Coil 110 V AC | |
| LC1D80004M7 | 4-pole, AC-1 125 A, 4NO | Coil 220 V AC | |
| LC1D80008E7 | 4-pole, AC-1 125 A, 2NO+2NC | Coil 48 V AC | |
| LC1D80008F7 | 4-pole, AC-1 125 A, 2NO+2NC | Coil 110 V AC | |
| LC1D80008M7 | 4-pole, AC-1 125 A, 2NO+2NC | Coil 220 V AC | |
| LC1D80AE7 | 3-pole, AC-3 80 A / 37 kW | Coil 48 V AC | |
| LC1D80AM7 | 3-pole, AC-3 80 A / 37 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D80B7 | 3-pole, AC-3 80 A / 37 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D80BD | 3-pole, AC-3 80 A / 37 kW | Coil 24 V DC; aux 1NO+1NC | |
| LC1D80E7 | 3-pole, AC-3 80 A / 37 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D80F7 | 3-pole, AC-3 80 A / 37 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D80M7 | 3-pole, AC-3 80 A / 37 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D80Q7 | 3-pole, AC-3 80 A / 37 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1D95B7 | 3-pole, AC-3 95 A / 45 kW | Coil 24 V AC; aux 1NO+1NC | |
| LC1D95BD | 3-pole, AC-3 95 A | Coil 24 V DC | |
| LC1D95E7 | 3-pole, AC-3 95 A / 45 kW | Coil 48 V AC; aux 1NO+1NC | |
| LC1D95F7 | 3-pole, AC-3 95 A / 45 kW | Coil 110 V AC; aux 1NO+1NC | |
| LC1D95M7 | 3-pole, AC-3 95 A / 45 kW | Coil 220 V AC; aux 1NO+1NC | |
| LC1D95P7 | 3-pole, AC-3 95 A / 45 kW | Coil 230 V AC; aux 1NO+1NC | |
| LC1D95Q7 | 3-pole, AC-3 95 A / 45 kW | Coil 380 V AC; aux 1NO+1NC | |
| LC1DFKM7 | Capacitor duty, 12.5 kvar | Coil 220 V AC | |
| LC1DGKM7 | Capacitor duty, 16.7 kvar | Coil 220 V AC | |
| LC1DLKM7 | Capacitor duty, 20 kvar | Coil 220 V AC | |
| LC1DMKM7 | Capacitor duty, 25 kvar | Coil 220 V AC | |
| LC1DPKM7 | Capacitor duty, 30 kvar | Coil 220 V AC | |
| LC1DTKM7 | Capacitor duty, 40 kvar | Coil 220 V AC | |
| LC1DWK12M7 | Capacitor duty, 60 kvar | Coil 220 V AC | |
| LC1DT20B7 | 4-pole, AC-1 20 A, 4NO | Coil 24 V AC | |
| LC1DT20BD | 4-pole, AC-1 20 A, 4NO | Coil 24 V DC | |
| LC1DT20M7 | 4-pole, AC-1 20 A, 4NO | Coil 220 V AC | |
| LC1DT25B7 | 4-pole, AC-1 25 A, 4NO | Coil 24 V AC | |
| LC1DT25E7 | 4-pole, AC-1 25 A, 4NO | Coil 48 V AC | |
| LC1DT25F7 | 4-pole, AC-1 25 A, 4NO | Coil 110 V AC | |
| LC1DT25M7 | 4-pole, AC-1 25 A, 4NO | Coil 220 V AC | |
| LC1DT25MD | 4-pole, AC-1 25 A, 4NO | Coil 220 V DC | |
| LC1DT32B7 | 4-pole, AC-1 32 A, 4NO | Coil 24 V AC | |
| LC1DT32E7 | 4-pole, AC-1 32 A, 4NO | Coil 48 V AC | |
| LC1DT32F7 | 4-pole, AC-1 32 A, 4NO | Coil 110 V AC | |
| LC1DT32M7 | 4-pole, AC-1 32 A, 4NO | Coil 220 V AC | |
| LC1DT40B7 | 4-pole, AC-1 40 A, 4NO | Coil 24 V AC | |
| LC1DT40E7 | 4-pole, AC-1 40 A, 4NO | Coil 48 V AC | |
| LC1DT40F7 | 4-pole, AC-1 40 A, 4NO | Coil 110 V AC | |
| LC1DT40M7 | 4-pole, AC-1 40 A, 4NO | Coil 220 V AC | |
| LC1DT40P7 | 4-pole, AC-1 40 A, 4NO | Coil 230 V AC | |
| LC1DT60AM7 | 4-pole, AC-1 60 A, 4NO | Coil 220 V AC | |
| LC1DT80AM7 | 4-pole, AC-1 80 A, 4NO | Coil 220 V AC |
TeSys D contactors: common questions
How do I read a Schneider LC1D code?
The number after LC1D is the AC-3 current in amps: LC1D09 = 9 A, LC1D32 = 32 A, LC1D65A = 65 A. The letters at the end are the coil voltage, for example LC1D18M7 = 18 A with a 220 V AC coil.
What do the coil letters M7, Q7, F7, B7 and BD mean?
On the TeSys D codes we list: B7 = 24 V AC, E7 = 48 V AC, F7 = 110 V AC, M7 = 220 V AC, P7 = 230 V AC, Q7 = 380 V AC, BD = 24 V DC, FD = 110 V DC, MD = 220 V DC. The coil must match your control circuit voltage.
Which LC1D size do I need for my motor?
Choose an AC-3 current equal to or above the motor nameplate current. As a guide from the ratings in our list: LC1D09 4 kW, D12 5.5 kW, D18 7.5 kW, D25 11 kW, D32 15 kW, D38 18.5 kW, D50A 22 kW, D65A 30 kW, D80 37 kW, D95 45 kW, D115 55 kW, D150 75 kW.
Which overload relay fits a TeSys D contactor?
Per Schneider, the TeSys Deca LRD thermal overload relays are made for the 9 to 38 A contactors (LC1D09 to LC1D38), and the LRD313 to LRD365 relays mount directly on LC1D40A to LC1D65A. Pick the relay whose setting range covers the motor current. For bigger sizes, send us the contactor code and the motor current.
Which contactor do I use for a capacitor bank?
Use a capacitor duty contactor, chosen by the step size in kvar. Our list has LC1DFK (12.5 kvar), LC1DGK (16.7), LC1DLK (20), LC1DMK (25), LC1DPK (30), LC1DTK (40) and LC1DWK12 (60 kvar).
My old contactor is another brand. Can you find the TeSys D equivalent?
Yes. Send the old part number or a photo of its label, plus the motor kW or current, the coil voltage and the auxiliary contacts you use. We match it by AC-3 current, coil voltage and contacts.