Product series • Schneider Electric

Schneider TeSys D Contactors (LC1D)

The Schneider TeSys D contactor (LC1D codes) is one of the most used contactors in motor control panels in Egypt. We list 3-pole types from 9 to 150 A AC-3, 4-pole AC-1 types, and capacitor duty contactors for power factor correction banks.

The number in the code is the current: LC1D09 = 9 A AC-3, LC1D32 = 32 A. The last letters give the coil voltage: M7 = 220 V AC, Q7 = 380 V AC, F7 = 110 V AC, B7 = 24 V AC and BD = 24 V DC.

How to choose

  1. Current and power: choose the contactor by its AC-3 (motor duty) current, equal to or above the motor nameplate current, or by AC-1 for resistive loads such as heaters.
  2. Coil voltage: must match your control circuit (for example 220 V AC or 24 V DC). The wrong voltage burns the coil or the contactor does not pull in.
  3. Auxiliary contacts: the NO and NC contacts you need for control and signals; add an auxiliary block if you need more.
  4. Capacitors: for power factor correction banks, use the capacitor duty contactor rated in kvar.

Can't find your code? Send the part number or a photo of the old part.

Part numbers we supply (142)

Part numberPoles, ratingCoil; auxiliary contacts
LC1D09B7 3-pole, AC-3 9 A / 4 kW Coil 24 V AC; aux 1NO+1NC
LC1D09BD 3-pole, AC-3 9 A / 4 kW Coil 24 V DC; aux 1NO+1NC
LC1D09E7 3-pole, AC-3 9 A / 4 kW Coil 48 V AC; aux 1NO+1NC
LC1D09F7 3-pole, AC-3 9 A / 4 kW Coil 110 V AC; aux 1NO+1NC
LC1D09FD 3-pole, AC-3 9 A / 4 kW Coil 110 V DC; aux 1NO+1NC
LC1D09M7 3-pole, AC-3 9 A / 4 kW Coil 220 V AC; aux 1NO+1NC
LC1D09MD 3-pole, AC-3 9 A / 4 kW Coil 220 V DC; aux 1NO+1NC
LC1D09P7 3-pole, AC-3 9 A / 4 kW Coil 230 V AC; aux 1NO+1NC
LC1D09Q7 3-pole, AC-3 9 A / 4 kW Coil 380 V AC; aux 1NO+1NC
LC1D115004M7 4-pole, 4NO Coil 220 V AC
LC1D115B7 3-pole, AC-3 115 A / 55 kW Coil 24 V AC; aux 1NO+1NC
LC1D115BD 3-pole, AC-3 115 A Coil 24 V DC
LC1D115E7 3-pole, AC-3 115 A / 55 kW Coil 48 V AC; aux 1NO+1NC
LC1D115F7 3-pole, AC-3 115 A / 55 kW Coil 110 V AC; aux 1NO+1NC
LC1D115M7 3-pole, AC-3 115 A / 55 kW Coil 220 V AC; aux 1NO+1NC
LC1D115Q7 3-pole, AC-3 115 A / 55 kW Coil 380 V AC; aux 1NO+1NC
LC1D128B7 4-pole, AC-1 25 A, 2NO+2NC Coil 24 V AC
LC1D128BD 4-pole, AC-1 25 A, 2NO+2NC Coil 24 V DC
LC1D128E7 4-pole, AC-1 25 A, 2NO+2NC Coil 48 V AC
LC1D128F7 4-pole, AC-1 25 A, 2NO+2NC Coil 110 V AC
LC1D128M7 4-pole, AC-1 25 A, 2NO+2NC Coil 220 V AC
LC1D12B7 3-pole, AC-3 12 A / 5.5 kW Coil 24 V AC; aux 1NO+1NC
LC1D12BD 3-pole, AC-3 12 A / 5.5 kW Coil 24 V DC; aux 1NO+1NC
LC1D12E7 3-pole, AC-3 12 A / 5.5 kW Coil 48 V AC; aux 1NO+1NC
LC1D12F7 3-pole, AC-3 12 A / 5.5 kW Coil 110 V AC; aux 1NO+1NC
LC1D12M7 3-pole, AC-3 12 A / 5.5 kW Coil 220 V AC; aux 1NO+1NC
LC1D12MD 3-pole, AC-3 12 A / 5.5 kW Coil 220 V DC; aux 1NO+1NC
LC1D12Q7 3-pole, AC-3 12 A / 5.5 kW Coil 380 V AC; aux 1NO+1NC
LC1D150B7 3-pole, AC-3 150 A / 75 kW Coil 24 V AC; aux 1NO+1NC
LC1D150E7 3-pole, AC-3 150 A / 75 kW Coil 48 V AC; aux 1NO+1NC
LC1D150F7 3-pole, AC-3 150 A / 75 kW Coil 110 V AC; aux 1NO+1NC
LC1D150M7 3-pole, AC-3 150 A / 75 kW Coil 220 V AC; aux 1NO+1NC
LC1D150Q7 3-pole, AC-3 150 A / 75 kW Coil 380 V AC; aux 1NO+1NC
LC1D18B7 3-pole, AC-3 18 A / 7.5 kW Coil 24 V AC; aux 1NO+1NC
LC1D18BD 3-pole, AC-3 18 A / 7.5 kW Coil 24 V DC; aux 1NO+1NC
LC1D18E7 3-pole, AC-3 18 A / 7.5 kW Coil 48 V AC; aux 1NO+1NC
LC1D18F7 3-pole, AC-3 18 A / 7.5 kW Coil 110 V AC; aux 1NO+1NC
LC1D18FD 3-pole, AC-3 18 A / 9 kW Coil 110 V DC; aux 1NO+1NC
LC1D18M7 3-pole, AC-3 18 A / 7.5 kW Coil 220 V AC; aux 1NO+1NC
LC1D18MD 3-pole, AC-3 18 A / 9 kW Coil 220 V DC; aux 1NO+1NC
LC1D18Q7 3-pole, AC-3 18 A / 7.5 kW Coil 380 V AC; aux 1NO+1NC
LC1D258B7 4-pole, AC-1 40 A, 2NO+2NC Coil 24 V AC
LC1D258E7 4-pole, AC-1 40 A, 2NO+2NC Coil 48 V AC
LC1D258F7 4-pole, AC-1 40 A, 2NO+2NC Coil 110 V AC
LC1D258M7 4-pole, AC-1 40 A, 2NO+2NC Coil 220 V AC
LC1D25B7 3-pole, AC-3 25 A / 11 kW Coil 24 V AC; aux 1NO+1NC
LC1D25BD 3-pole, AC-3 25 A / 11 kW Coil 24 V DC; aux 1NO+1NC
LC1D25E7 3-pole, AC-3 25 A / 11 kW Coil 48 V AC; aux 1NO+1NC
LC1D25F7 3-pole, AC-3 25 A / 11 kW Coil 110 V AC; aux 1NO+1NC
LC1D25M7 3-pole, AC-3 25 A / 11 kW Coil 220 V AC; aux 1NO+1NC
LC1D25P7 3-pole, AC-3 25 A / 11 kW Coil 230 V AC; aux 1NO+1NC
LC1D25Q7 3-pole, AC-3 25 A / 11 kW Coil 380 V AC; aux 1NO+1NC
LC1D32B7 3-pole, AC-3 32 A / 15 kW Coil 24 V AC; aux 1NO+1NC
LC1D32BD 3-pole, AC-3 32 A / 15 kW Coil 24 V DC; aux 1NO+1NC
LC1D32E7 3-pole, AC-3 32 A / 15 kW Coil 48 V AC; aux 1NO+1NC
LC1D32ED 3-pole, AC-3 32 A / 15 kW Coil 48 V DC; aux 1NO+1NC
LC1D32F7 3-pole, AC-3 32 A / 15 kW Coil 110 V AC; aux 1NO+1NC
LC1D32FD 3-pole, AC-3 32 A / 15 kW Coil 110 V DC; aux 1NO+1NC
LC1D32M7 3-pole, AC-3 32 A / 15 kW Coil 220 V AC; aux 1NO+1NC
LC1D32MD 3-pole, AC-3 32 A / 15 kW Coil 220 V DC; aux 1NO+1NC
LC1D32Q7 3-pole, AC-3 32 A / 15 kW Coil 380 V AC; aux 1NO+1NC
LC1D38B7 3-pole, AC-3 38 A / 18.5 kW Coil 24 V AC; aux 1NO+1NC
LC1D38BD 3-pole, AC-3 38 A / 18.5 kW Coil 24 V DC; aux 1NO+1NC
LC1D38E7 3-pole, AC-3 38 A / 18.5 kW Coil 48 V AC; aux 1NO+1NC
LC1D38F7 3-pole, AC-3 38 A / 18.5 kW Coil 110 V AC; aux 1NO+1NC
LC1D38M7 3-pole, AC-3 38 A / 18.5 kW Coil 220 V AC; aux 1NO+1NC
LC1D38Q7 3-pole, AC-3 38 A / 18.5 kW Coil 380 V AC; aux 1NO+1NC
LC1D40004P7 4-pole, 4NO Coil 230 V AC
LC1D40008E7 4-pole, AC-1 60 A, 2NO+2NC Coil 48 V AC
LC1D40008F7 4-pole, AC-1 60 A, 2NO+2NC Coil 110 V AC
LC1D40008M7 4-pole, AC-1 60 A, 2NO+2NC Coil 220 V AC
LC1D40A3M7 3-pole, AC-3 40 A, spring terminals Coil 220 V AC
LC1D40AB7 3-pole, AC-3 40 A / 18.5 kW Coil 24 V AC; aux 1NO+1NC
LC1D40ABNE 3-pole, AC-3 40 A / 18.5 kW Coil 24-60 V AC/DC; aux 1NO+1NC
LC1D40AE7 3-pole, AC-3 40 A / 18.5 kW Coil 48 V AC; aux 1NO+1NC
LC1D40AF7 3-pole, AC-3 40 A / 18.5 kW Coil 110 V AC; aux 1NO+1NC
LC1D40AM7 3-pole, AC-3 40 A / 18.5 kW Coil 220 V AC; aux 1NO+1NC
LC1D40AQ7 3-pole, AC-3 40 A / 18.5 kW Coil 380 V AC; aux 1NO+1NC
LC1D50A6M7 3-pole, AC-3 50 A / 22 kW, lug terminals Coil 220 V AC
LC1D50AB7 3-pole, AC-3 50 A / 22 kW Coil 24 V AC; aux 1NO+1NC
LC1D50ABNE 3-pole, AC-3 50 A / 22 kW Coil 24-60 V AC/DC; aux 1NO+1NC
LC1D50AE7 3-pole, AC-3 50 A / 22 kW Coil 48 V AC; aux 1NO+1NC
LC1D50AF7 3-pole, AC-3 50 A / 22 kW Coil 110 V AC; aux 1NO+1NC
LC1D50AM7 3-pole, AC-3 50 A / 22 kW Coil 220 V AC; aux 1NO+1NC
LC1D50AQ7 3-pole, AC-3 50 A / 22 kW Coil 380 V AC; aux 1NO+1NC
LC1D65008E7 4-pole, 2NO+2NC Coil 48 V AC
LC1D65008F7 4-pole, 2NO+2NC Coil 110 V AC
LC1D65008M7 4-pole, AC-1 80 A, 2NO+2NC Coil 220 V AC
LC1D65AB7 3-pole, AC-3 65 A / 30 kW Coil 24 V AC; aux 1NO+1NC
LC1D65ABNE 3-pole, AC-3 65 A / 30 kW Coil 24-60 V AC/DC; aux 1NO+1NC
LC1D65AE7 3-pole, AC-3 65 A / 30 kW Coil 48 V AC; aux 1NO+1NC
LC1D65AF7 3-pole, AC-3 65 A / 30 kW Coil 110 V AC; aux 1NO+1NC
LC1D65AM7 3-pole, AC-3 65 A / 30 kW Coil 220 V AC; aux 1NO+1NC
LC1D65AP7 3-pole, AC-3 65 A / 30 kW Coil 230 V AC
LC1D65AQ7 3-pole, AC-3 65 A / 30 kW Coil 380 V AC; aux 1NO+1NC
LC1D80004E7 4-pole, AC-1 125 A, 4NO Coil 48 V AC
LC1D80004F7 4-pole, AC-1 125 A, 4NO Coil 110 V AC
LC1D80004M7 4-pole, AC-1 125 A, 4NO Coil 220 V AC
LC1D80008E7 4-pole, AC-1 125 A, 2NO+2NC Coil 48 V AC
LC1D80008F7 4-pole, AC-1 125 A, 2NO+2NC Coil 110 V AC
LC1D80008M7 4-pole, AC-1 125 A, 2NO+2NC Coil 220 V AC
LC1D80AE7 3-pole, AC-3 80 A / 37 kW Coil 48 V AC
LC1D80AM7 3-pole, AC-3 80 A / 37 kW Coil 220 V AC; aux 1NO+1NC
LC1D80B7 3-pole, AC-3 80 A / 37 kW Coil 24 V AC; aux 1NO+1NC
LC1D80BD 3-pole, AC-3 80 A / 37 kW Coil 24 V DC; aux 1NO+1NC
LC1D80E7 3-pole, AC-3 80 A / 37 kW Coil 48 V AC; aux 1NO+1NC
LC1D80F7 3-pole, AC-3 80 A / 37 kW Coil 110 V AC; aux 1NO+1NC
LC1D80M7 3-pole, AC-3 80 A / 37 kW Coil 220 V AC; aux 1NO+1NC
LC1D80Q7 3-pole, AC-3 80 A / 37 kW Coil 380 V AC; aux 1NO+1NC
LC1D95B7 3-pole, AC-3 95 A / 45 kW Coil 24 V AC; aux 1NO+1NC
LC1D95BD 3-pole, AC-3 95 A Coil 24 V DC
LC1D95E7 3-pole, AC-3 95 A / 45 kW Coil 48 V AC; aux 1NO+1NC
LC1D95F7 3-pole, AC-3 95 A / 45 kW Coil 110 V AC; aux 1NO+1NC
LC1D95M7 3-pole, AC-3 95 A / 45 kW Coil 220 V AC; aux 1NO+1NC
LC1D95P7 3-pole, AC-3 95 A / 45 kW Coil 230 V AC; aux 1NO+1NC
LC1D95Q7 3-pole, AC-3 95 A / 45 kW Coil 380 V AC; aux 1NO+1NC
LC1DFKM7 Capacitor duty, 12.5 kvar Coil 220 V AC
LC1DGKM7 Capacitor duty, 16.7 kvar Coil 220 V AC
LC1DLKM7 Capacitor duty, 20 kvar Coil 220 V AC
LC1DMKM7 Capacitor duty, 25 kvar Coil 220 V AC
LC1DPKM7 Capacitor duty, 30 kvar Coil 220 V AC
LC1DTKM7 Capacitor duty, 40 kvar Coil 220 V AC
LC1DWK12M7 Capacitor duty, 60 kvar Coil 220 V AC
LC1DT20B7 4-pole, AC-1 20 A, 4NO Coil 24 V AC
LC1DT20BD 4-pole, AC-1 20 A, 4NO Coil 24 V DC
LC1DT20M7 4-pole, AC-1 20 A, 4NO Coil 220 V AC
LC1DT25B7 4-pole, AC-1 25 A, 4NO Coil 24 V AC
LC1DT25E7 4-pole, AC-1 25 A, 4NO Coil 48 V AC
LC1DT25F7 4-pole, AC-1 25 A, 4NO Coil 110 V AC
LC1DT25M7 4-pole, AC-1 25 A, 4NO Coil 220 V AC
LC1DT25MD 4-pole, AC-1 25 A, 4NO Coil 220 V DC
LC1DT32B7 4-pole, AC-1 32 A, 4NO Coil 24 V AC
LC1DT32E7 4-pole, AC-1 32 A, 4NO Coil 48 V AC
LC1DT32F7 4-pole, AC-1 32 A, 4NO Coil 110 V AC
LC1DT32M7 4-pole, AC-1 32 A, 4NO Coil 220 V AC
LC1DT40B7 4-pole, AC-1 40 A, 4NO Coil 24 V AC
LC1DT40E7 4-pole, AC-1 40 A, 4NO Coil 48 V AC
LC1DT40F7 4-pole, AC-1 40 A, 4NO Coil 110 V AC
LC1DT40M7 4-pole, AC-1 40 A, 4NO Coil 220 V AC
LC1DT40P7 4-pole, AC-1 40 A, 4NO Coil 230 V AC
LC1DT60AM7 4-pole, AC-1 60 A, 4NO Coil 220 V AC
LC1DT80AM7 4-pole, AC-1 80 A, 4NO Coil 220 V AC

TeSys D contactors: common questions

How do I read a Schneider LC1D code?

The number after LC1D is the AC-3 current in amps: LC1D09 = 9 A, LC1D32 = 32 A, LC1D65A = 65 A. The letters at the end are the coil voltage, for example LC1D18M7 = 18 A with a 220 V AC coil.

What do the coil letters M7, Q7, F7, B7 and BD mean?

On the TeSys D codes we list: B7 = 24 V AC, E7 = 48 V AC, F7 = 110 V AC, M7 = 220 V AC, P7 = 230 V AC, Q7 = 380 V AC, BD = 24 V DC, FD = 110 V DC, MD = 220 V DC. The coil must match your control circuit voltage.

Which LC1D size do I need for my motor?

Choose an AC-3 current equal to or above the motor nameplate current. As a guide from the ratings in our list: LC1D09 4 kW, D12 5.5 kW, D18 7.5 kW, D25 11 kW, D32 15 kW, D38 18.5 kW, D50A 22 kW, D65A 30 kW, D80 37 kW, D95 45 kW, D115 55 kW, D150 75 kW.

Which overload relay fits a TeSys D contactor?

Per Schneider, the TeSys Deca LRD thermal overload relays are made for the 9 to 38 A contactors (LC1D09 to LC1D38), and the LRD313 to LRD365 relays mount directly on LC1D40A to LC1D65A. Pick the relay whose setting range covers the motor current. For bigger sizes, send us the contactor code and the motor current.

Which contactor do I use for a capacitor bank?

Use a capacitor duty contactor, chosen by the step size in kvar. Our list has LC1DFK (12.5 kvar), LC1DGK (16.7), LC1DLK (20), LC1DMK (25), LC1DPK (30), LC1DTK (40) and LC1DWK12 (60 kvar).

My old contactor is another brand. Can you find the TeSys D equivalent?

Yes. Send the old part number or a photo of its label, plus the motor kW or current, the coil voltage and the auxiliary contacts you use. We match it by AC-3 current, coil voltage and contacts.