Siemens SIRIUS 3RT Contactors
Siemens SIRIUS 3RT2 contactors for motor control from 7 to 110 A AC-3, 3RT1 for larger sizes up to 500 A, and 3TF68/69 up to 820 A.
We also list 3RT26 capacitor duty contactors, 5TT modular contactors for distribution boards and a 3RF solid-state contactor.
How to choose
- Current and power: choose the contactor by its AC-3 (motor duty) current, equal to or above the motor nameplate current, or by AC-1 for resistive loads such as heaters.
- Coil voltage: must match your control circuit (for example 220 V AC or 24 V DC). The wrong voltage burns the coil or the contactor does not pull in.
- Auxiliary contacts: the NO and NC contacts you need for control and signals; add an auxiliary block if you need more.
- Capacitors: for power factor correction banks, use the capacitor duty contactor rated in kvar.
Can't find your code? Send the part number or a photo of the old part.
Part numbers we supply (97)
| Part number | Poles, rating | Coil; auxiliary contacts | |
|---|---|---|---|
| 3RT2015-1AB01 | 3-pole, AC-3 7 A / 3 kW, AC-1 18 A | Coil 24 V AC; aux 1NO | |
| 3RT2015-1BB41 | 3-pole, AC-3 7 A / 3 kW, AC-1 18 A | Coil 24 V DC; aux 1NO | |
| 3RT2015-1AF01 | 3-pole, AC-3 7 A / 3 kW, AC-1 18 A | Coil 110 V AC; aux 1NO | |
| 3RT2015-1AP01 | 3-pole, AC-3 7 A / 3 kW, AC-1 18 A | Coil 220 V AC; aux 1NO | |
| 3RT2016-1AB01 | 3-pole, AC-3 9 A / 4 kW, AC-1 22 A | Coil 24 V AC; aux 1NO | |
| 3RT2016-1BB41 | 3-pole, AC-3 9 A / 4 kW, AC-1 22 A | Coil 24 V DC; aux 1NO | |
| 3RT2016-1AF01 | 3-pole, AC-3 9 A / 4 kW, AC-1 22 A | Coil 110 V AC; aux 1NO | |
| 3RT2016-1AP01 | 3-pole, AC-3 9 A / 4 kW, AC-1 22 A | Coil 220 V AC; aux 1NO | |
| 3RT2017-1AB01 | 3-pole, AC-3 12 A / 5.5 kW, AC-1 22 A | Coil 24 V AC; aux 1NO | |
| 3RT2017-1BB41 | 3-pole, AC-3 12 A / 5.5 kW, AC-1 22 A | Coil 24 V DC; aux 1NO | |
| 3RT2017-1AF01 | 3-pole, AC-3 12 A / 5.5 kW, AC-1 22 A | Coil 110 V AC; aux 1NO | |
| 3RT2017-1AP01 | 3-pole, AC-3 12 A / 5.5 kW, AC-1 22 A | Coil 220 V AC; aux 1NO | |
| 3RT2018-1AB01 | 3-pole, AC-3 17 A / 7.5 kW, AC-1 22 A | Coil 24 V AC; aux 1NO | |
| 3RT2018-1BB41 | 3-pole, AC-3 17 A / 7.5 kW, AC-1 22 A | Coil 24 V DC; aux 1NO | |
| 3RT2018-1AF01 | 3-pole, AC-3 17 A / 7.5 kW, AC-1 22 A | Coil 110 V AC; aux 1NO | |
| 3RT2018-1AP01 | 3-pole, AC-3 17 A / 7.5 kW, AC-1 22 A | Coil 220 V AC; aux 1NO | |
| 3RT2023-1AB00 | 3-pole, AC-3 9 A / 4 kW, AC-1 40 A | Coil 24 V AC; aux 1NO+1NC | |
| 3RT2023-1BB40 | 3-pole, AC-3 9 A / 4 kW, AC-1 40 A | Coil 24 V DC; aux 1NO+1NC | |
| 3RT2023-1AF00 | 3-pole, AC-3 9 A / 4 kW, AC-1 40 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2023-1AP00 | 3-pole, AC-3 9 A / 4 kW, AC-1 40 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2024-1AB00 | 3-pole, AC-3 12 A / 5.5 kW, AC-1 40 A | Coil 24 V AC; aux 1NO+1NC | |
| 3RT2024-1BB40 | 3-pole, AC-3 12 A / 5.5 kW, AC-1 40 A | Coil 24 V DC; aux 1NO+1NC | |
| 3RT2024-1AF00 | 3-pole, AC-3 12 A / 5.5 kW, AC-1 40 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2024-1AP00 | 3-pole, AC-3 12 A / 5.5 kW, AC-1 40 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2024-1AH00 | 3-pole, AC-3 12 A / 5.5 kW, AC-1 40 A | Coil 48 V AC; aux 1NO+1NC | |
| 3RT2025-1AB00 | 3-pole, AC-3 17 A / 7.5 kW, AC-1 40 A | Coil 24 V AC; aux 1NO+1NC | |
| 3RT2025-1BB40 | 3-pole, AC-3 17 A / 7.5 kW, AC-1 40 A | Coil 24 V DC; aux 1NO+1NC | |
| 3RT2025-1AF00 | 3-pole, AC-3 17 A / 7.5 kW, AC-1 40 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2025-1AP00 | 3-pole, AC-3 17 A / 7.5 kW, AC-1 40 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2025-1AH00 | 3-pole, AC-3 17 A / 7.5 kW, AC-1 40 A | Coil 48 V AC; aux 1NO+1NC | |
| 3RT2026-1AB00 | 3-pole, AC-3 25 A / 11 kW, AC-1 40 A | Coil 24 V AC; aux 1NO+1NC | |
| 3RT2026-1BB40 | 3-pole, AC-3 25 A / 11 kW, AC-1 40 A | Coil 24 V DC; aux 1NO+1NC | |
| 3RT2026-1AF00 | 3-pole, AC-3 25 A / 11 kW, AC-1 40 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2026-1AP00 | 3-pole, AC-3 25 A / 11 kW, AC-1 40 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2026-1AD00 | 3-pole, AC-3 25 A / 11 kW, AC-1 40 A | Coil 42 V AC; aux 1NO+1NC | |
| 3RT2026-1AV00 | 3-pole, AC-3 25 A / 11 kW, AC-1 40 A | Coil 400 V AC; aux 1NO+1NC | |
| 3RT2027-1AB00 | 3-pole, AC-3 32 A / 15 kW, AC-1 50 A | Coil 24 V AC; aux 1NO+1NC | |
| 3RT2027-1BB40 | 3-pole, AC-3 32 A / 15 kW, AC-1 50 A | Coil 24 V DC; aux 1NO+1NC | |
| 3RT2027-1AF00 | 3-pole, AC-3 32 A / 15 kW, AC-1 50 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2027-1AP00 | 3-pole, AC-3 32 A / 15 kW, AC-1 50 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2027-1AH00 | 3-pole, AC-3 32 A / 15 kW, AC-1 50 A | Coil 48 V AC; aux 1NO+1NC | |
| 3RT2028-1AB00 | 3-pole, AC-3 38 A / 18.5 kW, AC-1 50 A | Coil 24 V AC; aux 1NO+1NC | |
| 3RT2028-1BB40 | 3-pole, AC-3 38 A / 18.5 kW, AC-1 50 A | Coil 24 V DC; aux 1NO+1NC | |
| 3RT2028-1AF00 | 3-pole, AC-3 38 A / 18.5 kW, AC-1 50 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2028-1AP00 | 3-pole, AC-3 38 A / 18.5 kW, AC-1 50 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2028-1AV00 | 3-pole, AC-3 38 A / 18.5 kW, AC-1 50 A | Coil 400 V AC; aux 1NO+1NC | |
| 3RT2035-1AP00 | 3-pole, AC-3 41 A / 18.5 kW, AC-1 60 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2035-1AF00 | 3-pole, AC-3 41 A / 18.5 kW, AC-1 60 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2035-1NB30 | 3-pole, AC-3 41 A / 18.5 kW, AC-1 60 A | Coil 20 – 33 V AC/DC; aux 1NO+1NC | |
| 3RT2036-1AP00 | 3-pole, AC-3 50 A / 22 kW, AC-1 70 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2036-1AB00 | 3-pole, AC-3 50 A / 22 kW, AC-1 70 A | Coil 24 V AC; aux 1NO+1NC | |
| 3RT2036-1AF00 | 3-pole, AC-3 50 A / 22 kW, AC-1 70 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2036-1NB30 | 3-pole, AC-3 50 A / 22 kW, AC-1 70 A | Coil 20 – 33 V AC/DC; aux 1NO+1NC | |
| 3RT2037-1AP00 | 3-pole, AC-3 65 A / 30 kW, AC-1 80 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2037-1AB00 | 3-pole, AC-3 65 A / 30 kW, AC-1 80 A | Coil 24 V AC; aux 1NO+1NC | |
| 3RT2037-1AF00 | 3-pole, AC-3 65 A / 30 kW, AC-1 80 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2037-1NB30 | 3-pole, AC-3 65 A / 30 kW, AC-1 80 A | Coil 20 – 33 V AC/DC; aux 1NO+1NC | |
| 3RT2038-1AP00 | 3-pole, AC-3 80 A / 37 kW, AC-1 90 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2038-1AB00 | 3-pole, AC-3 80 A / 37 kW, AC-1 90 A | Coil 24 V AC; aux 1NO+1NC | |
| 3RT2038-1AF00 | 3-pole, AC-3 80 A / 37 kW, AC-1 90 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2038-1NB30 | 3-pole, AC-3 80 A / 37 kW, AC-1 90 A | Coil 20 – 33 V AC/DC; aux 1NO+1NC | |
| 3RT2046-1AP00 | 3-pole, AC-3 90 A / 45 kW, AC-1 130 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2046-1AF00 | 3-pole, AC-3 90 A / 45 kW, AC-1 130 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT2046-1AV00 | 3-pole, AC-3 90 A / 45 kW, AC-1 130 A | Coil 400 V AC; aux 1NO+1NC | |
| 3RT2047-1AP00 | 3-pole, AC-3 110 A / 55 kW, AC-1 130 A | Coil 220 V AC; aux 1NO+1NC | |
| 3RT2047-1AF00 | 3-pole, AC-3 110 A / 55 kW, AC-1 130 A | Coil 110 V AC; aux 1NO+1NC | |
| 3RT1054-1AF36 | 3-pole, AC-3 115 A / 55 kW, AC-1 160 A | Coil 110 V AC/DC; aux 2NO+2NC | |
| 3RT1054-1AP36 | 3-pole, AC-3 115 A / 55 kW, AC-1 160 A | Coil 220 V AC/DC; aux 2NO+2NC | |
| 3RT1054-1AB36 | 3-pole, AC-3 115 A / 55 kW, AC-1 160 A | Coil 24 V AC/DC; aux 2NO+2NC | |
| 3RT1055-6AF36 | 3-pole, AC-3 150 A / 75 kW, AC-1 185 A | Coil 110 V AC/DC; aux 2NO+2NC | |
| 3RT1055-6AP36 | 3-pole, AC-3 150 A / 75 kW, AC-1 185 A | Coil 220 V AC/DC; aux 2NO+2NC | |
| 3RT1056-6AF36 | 3-pole, AC-3 185 A / 90 kW, AC-1 215 A | Coil 110 V AC/DC; aux 2NO+2NC | |
| 3RT1056-6AP36 | 3-pole, AC-3 185 A / 90 kW, AC-1 215 A | Coil 220 V AC/DC; aux 2NO+2NC | |
| 3RT1056-6AB36 | 3-pole, AC-3 185 A / 90 kW, AC-1 215 A | Coil 24 V AC/DC; aux 2NO+2NC | |
| 3RT1064-6AF36 | 3-pole, AC-3 225 A / 110 kW, AC-1 275 A | Coil 110 V AC/DC; aux 2NO+2NC | |
| 3RT1064-6AP36 | 3-pole, AC-3 225 A / 110 kW, AC-1 275 A | Coil 220 V AC/DC; aux 2NO+2NC | |
| 3RT1065-6AF36 | 3-pole, AC-3 265 A / 132 kW, AC-1 330 A | Coil 110 V AC/DC; aux 2NO+2NC | |
| 3RT1065-6AP36 | 3-pole, AC-3 265 A / 132 kW, AC-1 330 A | Coil 220 V AC/DC; aux 2NO+2NC | |
| 3RT1066-6AF36 | 3-pole, AC-3 300 A / 160 kW, AC-1 330 A | Coil 110 V AC/DC; aux 2NO+2NC | |
| 3RT1066-6AP36 | 3-pole, AC-3 300 A / 160 kW, AC-1 330 A | Coil 220 V AC/DC; aux 2NO+2NC | |
| 3RT1075-6AF36 | 3-pole, AC-3 400 A / 200 kW, AC-1 430 A | Coil 110 V AC/DC; aux 2NO+2NC | |
| 3RT1075-6AP36 | 3-pole, AC-3 400 A / 200 kW, AC-1 430 A | Coil 220 V AC/DC; aux 2NO+2NC | |
| 3RT1076-6AF36 | 3-pole, AC-3 500 A / 250 kW, AC-1 610 A | Coil 110 V AC/DC; aux 2NO+2NC | |
| 3RT1076-6AP36 | 3-pole, AC-3 500 A / 250 kW, AC-1 610 A | Coil 220 V AC/DC; aux 2NO+2NC | |
| 3TF6844-0CM7 | 3-pole, AC-3 630 A / 335 kW, AC-1 700 A | Coil 220 V AC; aux 4NO+4NC | |
| 3TF6944-0CM7 | 3-pole, AC-3 820 A / 450 kW, AC-1 910 A | Coil 220 V AC; aux 4NO+4NC | |
| 3RT2617-1AP03 | Capacitor duty, 12.5 kvar, size S00 | Coil 230/220 V AC; aux 1NO+1NC | |
| 3RT2627-1AP05 | Capacitor duty, 25 kvar, size S00 | Coil 230/220 V AC; aux 1NO+2NC | |
| 3RT2636-1AP03 | Capacitor duty, 50 kvar, size S2 | Coil 230/220 V AC; aux 1NO+1NC | |
| 3RT2637-1AP03 | Capacitor duty, 75 kvar, size S2 | Coil 230/220 V AC; aux 1NO+1NC | |
| 5TT4101-0 | Modular contactor, 16 A | 1NO; coil 220 V AC | |
| 5TT4102-0 | Modular contactor, 16 A | 2NO; coil 220 V AC | |
| 5TT5800-0 | Modular contactor, 20 A | 2NO; coil 220 V AC | |
| 5TT5831-0 | Modular contactor, 25 A | 3NO+1NC; coil 220 V AC | |
| 5TT5841-0 | Modular contactor, 40 A | 3NO+1NC; coil 220 V AC | |
| 5TT5851-0 | Modular contactor, 63 A | 3NO+1NC; coil 220 V AC | |
| 3RF3320-1AA45 | Solid-state contactor, 1-pole, AC-1 20 A, 48-600 V | Control 4-30 V DC |
Siemens SIRIUS 3RT contactors: common questions
How do I read a Siemens 3RT2 code?
The digit after 3RT20 gives the size: 3RT201x = size S00, 3RT202x = S0, 3RT203x = S2, 3RT204x = S3. The last digit of that group sets the current, for example 3RT2016 = 9 A AC-3 (4 kW) and 3RT2026 = 25 A (11 kW). The letters after the dash give the coil voltage.
What do the coil codes AP, AF, AB and BB mean?
On the 3RT2 codes we list: AP = 220/230 V AC, AF = 110 V AC, AH = 48 V AC, AB = 24 V AC, AV = 400 V AC, BB = 24 V DC, and NB = 20 to 33 V AC/DC. Example: 3RT2016-1AP01 has a 220 V AC coil, 3RT2016-1BB41 a 24 V DC coil.
Which 3RT size do I need for my motor?
Choose an AC-3 current equal to or above the motor nameplate current. From the ratings in our list: 3RT2015 3 kW, 2016 4 kW, 2017 5.5 kW, 2018 7.5 kW, 2026 11 kW, 2027 15 kW, 2028 18.5 kW, 2036 22 kW, 2037 30 kW, 2038 37 kW, 2046 45 kW, 2047 55 kW. Larger motors use 3RT1 (up to 500 A in our list).
Which overload relay fits a 3RT2 contactor?
Use a 3RU2 thermal overload relay of the same size, so it mounts directly: size S00 relays on 3RT201x, S0 on 3RT202x, S2 on 3RT203x, S3 on 3RT204x. Then pick the setting range that covers the motor current. Send us the contactor code and motor current if you are not sure.
Which Siemens contactor do I use for a capacitor bank?
Use a 3RT26 capacitor duty contactor, chosen by the step size in kvar. Our list has 3RT2617 (12.5 kvar), 3RT2627 (25 kvar), 3RT2636 (50 kvar) and 3RT2637 (75 kvar).
My old contactor is another brand. Can you find the Siemens equivalent?
Yes. Send the old part number or a photo of its label, plus the motor kW or current, the coil voltage and the auxiliary contacts you use. We match it by AC-3 current, coil voltage and contacts.